1. Destpêk
The ThermoWorks Splash-Proof Super-Fast Thermapen is a professional-grade digital thermometer designed for rapid and accurate temperature measurement. Utilizing advanced thermocouple technology, it provides precise readings in seconds, making it ideal for various applications, including culinary use. Its robust, splash-proof design ensures durability and reliability in demanding environments.
Each Thermapen unit undergoes rigorous testing and comes with a NIST-traceable certificate, guaranteeing its accuracy. The intuitive fold-away probe design eliminates the need for external cables, offering convenience and preventing snags or bacterial traps often associated with traditional probe thermometers.
2. Taybetmendiyên Hilberê
- Super-Fast Readings: Provides accurate temperature readings in approximately 3 seconds.
- Rastiya Bilind: Calibrated to ±0.7°F (±0.4°C) across its full range.
- Sêwirana Splash-Proof: Molded-in seals protect the thermometer from splashes and moisture, suitable for kitchen use.
- Fold-Away Probe: Convenient and safe storage, eliminating external cables.
- Digital Display: Clear, easy-to-read digital display with 0.1° resolution.
- Otomatîk On / Off: Simply open the probe to turn on and fold it away to turn off.
- Yekîneyên Hilbijartî: Bi hêsanî di navbera Celsius (°C) û Fahrenheit (°F) de biguherin.
- NIST-Traceable Certificate: Each unit includes a certificate of calibration.
3. Sazkirin û Bikaranîna Destpêkê
- Sazkirina Pîlê: The Thermapen comes with one AAA battery pre-installed. To access the battery compartment, locate the battery cover on the back of the unit. Use a small screwdriver to open it if necessary. Ensure the battery is correctly oriented according to the polarity markings.
- Power On / Off: To turn the Thermapen on, simply unfold the probe until it locks into place. The display will illuminate. To turn it off, fold the probe back into the body of the thermometer.
- Selecting Temperature Units (°C/°F):
Inside the battery compartment, there is a small switch or button to toggle between Celsius (°C) and Fahrenheit (°F). Use a pen tip or a small pointed object to press or slide this switch to your desired unit.

Figure 1: Cleaning the Thermapen probe. The battery compartment is typically located on the back of the unit, near where the probe folds.
- Resolution Adjustment (0.1° or 1°): Some models may offer an option to switch between 0.1° and 1° resolution. This setting is also typically found within the battery compartment. Refer to the markings inside for specific instructions.
4. Telîmatên Operating
- Termometre amade bikin: Unfold the probe to turn on the unit. Ensure the desired temperature unit (°C or °F) is selected.
- Probe têxe: Carefully insert the stainless steel probe into the center of the food or liquid you wish to measure. For best accuracy, ensure the probe tip is fully immersed and not touching any bones or the bottom of the pan.
- Germahiya bixwînin: The digital display will show the temperature reading within approximately 3 seconds. Wait for the reading to stabilize for the most accurate result.
- Remove and Clean: After use, remove the probe from the item. Fold the probe back into the body to turn off the unit. Clean the probe thoroughly as described in the Maintenance section.

Figure 2: Measuring the internal temperature of food with the Thermapen.
5. Maintenance û Care
- Paqijkirina sondajê: Always clean the stainless steel probe after each use to prevent cross-contamination. Wipe the probe with an antibacterial wipe or a damp cloth with mild soap and water. Rinse thoroughly.
- Paqijkirina laş: The Thermapen body is splash-proof and can be wiped clean with a damp cloth. Do not immerse the entire unit in water or place it in a dishwasher.
- Embarkirinî: Store the Thermapen with the probe folded away in a clean, dry place. The fold-away design protects the probe and prevents accidental activation.
- Guhertina Pîl: When the display indicates a low battery, replace the AAA battery. Ensure proper polarity during installation.
- Calibration: The Thermapen is factory calibrated and comes with a NIST-traceable certificate. Routine user calibration is generally not required. If you suspect a significant deviation, contact ThermoWorks support.
6. Destpêkirin
| Pirsegirêk | Sedema gengaz | Çare |
|---|---|---|
| Nîşandan vala an tarî ye. | Pîlê kêm an jî mirî. Sazkirina pîlê şaş e. | Replace the AAA battery. Ensure the battery is inserted with correct polarity. |
| Xwendinên nerast. | Probe not fully inserted. Probe tip touching bone or pan. Unit needs recalibration (rare). | Ensure probe tip is in the center of the food/liquid. Avoid contact with bones/pan. Contact support if issues persist. |
| Unit does not turn on/off automatically. | Probe not fully extended or folded. | Ensure the probe is fully extended until it clicks, or fully folded into the body. |
7. Specifications
| Cins | THS-231-207 |
| Nîşan | ThermoWorks |
| Rêzeya Pîvan | -58 heta 572°F (-50 heta 300°C) |
| Tamî | ±0.7°F (±0.4°C) |
| Resolution | 0.1° (selectable to 1°) |
| Dema bersivê | Nêzîkî 3 çirke |
| Çavkaniya Hêzê | 1 x Pîl AAA (tevî) |
| Type Display | Digital |
| Materyalê Derveyî | Pîlastîk |
| Telîmatên lênêrînê | Paqij bike |
| Dimensions | 16 x 12.2 x 1.3 cm (pêçandî) |
| Compliance Standard | NSF |

Figure 3: ThermoWorks Thermapen in various colors.
8. Garantî û Piştgirî
ThermoWorks products are known for their quality and reliability. For specific warranty information, please refer to the documentation included with your purchase or visit the official ThermoWorks website. For technical support, troubleshooting assistance, or to inquire about calibration services, please contact ThermoWorks customer service directly.
Çavkaniyên Serhêl: For additional information, FAQs, and product registration, please visit the official ThermoWorks webmalper: www.thermoworks.com