ORTECH-logo

ORTECH ERV-SC-1 Screen Controller

ORTECH-ERV-SC-1-Screen-Controller-product

Specifications

  • Navê Berhemê: KONTROLA DÎMENA ERV ERV-SC-1
  • Çêkirin: Dîwarî
  • Features: Ultra-thin wired controller, OCA-bonded capacitive touch screen, Adjustable brightness
  • Power Source: Powered by ERV, no battery required

HIŞYARÎ

Wall-Mounted, Screen Controller for Energy Recovery Ventilators

  • Ultra-thin wired controller
  • OCA bonded capacitive touch screen Easy installation
  • Powered by ERV, no battery required
  • Ronahiya birêkûpêk
  • Bi ber viewing angle

GAZÎ

JI BO KÊM KIRINA RÊSTIYA AGIRTÎ, ŞOKA ELEKTRIKÊ AN JI BIRÎNDARÊ LI KESAN KÊM BIKE, LI JÊRÊN HIŞYAR BIN:

  • Vê yekîneyê tenê bi awayê ku ji hêla çêker ve hatî armanc kirin bikar bînin.
  • Before servicing or cleaning unit, switch power off.
  • Karê sazkirinê û têlên elektrîkê divê li gorî hemî kod û standardên derbasdar, di nav de kod û standardên avahîsaziyê yên bi nirxa agir, ji hêla kesek(yên) pispor ve bêne kirin.
  • Dema ku di dîwêr de qut bikin an jî lêxin, zirarê nedin têlên elektrîkê û karûbarên din ên veşartî.

BALDAYNÎ

  • Read all instructions before installing or using this unit.
  • To reduce the risk of fire, remove any shipping material that may be present inside the unit.
  • Hemî girêdanên têlan kontrol bikin da ku ew kapasîteya heyî ya rast bicîh bînin.
  • After connecting the ERV-SC-1, please keep the knobs on the control board at the factory settings (100CFM).

DIAGRAMA WIRING

ORTECH-ERV-SC-1-Screen-Controller-fig-8

HARDWARE NAVEROK

ORTECH-ERV-SC-1-Screen-Controller-fig-2RÊBAZÊN MECLÎSÊ

  1. Using straight screwdriver, pry off the bracket of the ERV-SC-1.
  2. Install the bracket to the wall using two screws. Ensure the bracket is oriented correctly (up).ORTECH-ERV-SC-1-Screen-Controller-fig-3
  3. Connect wire to terminals on the ERV-SC-1, note which wire color has been chosen for each terminal.
  4. Install the ERV-SC-1 to the bracket without using screws, the ERV-SC-1 can be fixed by the tabs.ORTECH-ERV-SC-1-Screen-Controller-fig-4Em pêşniyar dikin ku ji bo her termînalê rengên têl ên jêrîn bikar bînin:
    • Red for “12V”,
    • Yellow for “A”,
    • Green for “B”,
    • Black for “0V”.
  5. Connect wires to terminals on the unit.
    Note: Match the wire color with the right terminal, red wire to terminal “12V”, yellow wire to terminal “A”, green wire to terminal “B”, black wire to terminal “0V”.
  6. After connecting the ERV-SC-1, please keep the knobs on the control board at the factory settings (100CFM).

BALDAYNÎ

Please connect according to the requirements, do not connect incorrectly, otherwise it may cause electrical damage.

DISPLAY CONTROLLER OPERATION

ORTECH-ERV-SC-1-Screen-Controller-fig-5ORTECH-ERV-SC-1-Screen-Controller-fig-6

Operasyon

  1. Press the ON button to let the unit ventilate continuously.
    • a. W hen the outdoor temperature is higher than -10°C, the unit will run continuously.
    • b . When the outdoor temperature is less than -10°C, the unit run as per the Temperature Sensor Operation tables in manual.
  2. Press the ECO button to set the running time per hour. The unit will run as follows:
    • 10min: run 5min, st op 25min;
    • 15min: run 5min, st op 15min;
    • 2 0min: run 5min, stop 10min;
    • 25-5 5min: run as per the set time once per hour.
  3. When the outdoor temperature and humidity is out of OA limit of temperature and humidity range, the unit will run as per a 5 min on/ 15 min off cycle. OA limit of temperature and humidity setting range is as follows:
    • Temperature High: 68-113°F
    • Temperature Low: 14-50°F
    • Humidi ty High: 45-99%
    • Humidi ty Low: 10-40%

PÊŞKIRINA TÊŞÎ

ORTECH-ERV-SC-1-Screen-Controller-fig-7

BALDAYNÎ

In addition to the display, the unit also provides alarm reminders. The alarm buzzer sounds every 4 hours, lasting for 5 seconds each time.

  • During the FILTER CHECK OR MAINTENANCE alarm, there will be a popup page showing: Pause, Continue or Reset.
  • All alarms can be exited by pressing the return button to go back to the main interface. And by clicking the “ORTECH-ERV-SC-1-Screen-Controller-fig-9 ” icon, the alarm interface can be displayed again.
  • If the screen is not powered, please check the ERV unit is powered on, the display is powered by the ERV unit.

ORTECH-ERV-SC-1-Screen-Controller-fig-10

ORTECH mafê xwe diparêze ku di her kêliyê de, bêyî agahdarî, yek an hemî taybetmendî, sêwiran, pêkhate û taybetmendiyên hilberê me biguhezîne da ku bi guheztinên bazarê re hevdîtin pêk bîne.

More Imfo

FAQ

Pirs: Ger piştî sazkirinê ez bi pirsgirêkên elektrîkê re rû bi rû bim divê ez çi bikim?

A: If you encounter any electrical issues after installation, immediately switch off power and consult a qualified professional to inspect and resolve the problem.

Q: Can I adjust the brightness of the screen on the ERV-SC-1?

A: Yes, the ERV-SC-1 features adjustable brightness to suit your preferences.

Belge / Çavkanî

ORTECH ERV-SC-1 Screen Controller [pdf] Rêbernameya Rêwerzan
ERV-SC-1, ERV-SC-1 Screen Controller, Screen Controller, Controller

Çavkanî

Bihêle şîroveyek

Navnîşana e-nameya we nayê weşandin. Zeviyên pêwîst têne nîşankirin *