TRACEABLE AO-94460-73

TRACEABLE Jumbo Calibrated Digital Fridge/Freezer Thermometer

Model: AO-94460-73

TRACEABLE Jumbo Calibrated Digital Fridge/Freezer Thermometer with Bottle Probe

Image: TRACEABLE Jumbo Calibrated Digital Fridge/Freezer Thermometer with its bottle probe.

1. Destpêk

The TRACEABLE Jumbo Calibrated Digital Fridge/Freezer Thermometer (Model AO-94460-73) is designed for precise temperature monitoring in refrigerators, freezers, water baths, heating blocks, and incubators. This device simultaneously displays current, minimum, and maximum temperatures, offering a comprehensive overview of environmental conditions. Its built-in memory stores temperature data, and programmable alarms provide alerts for critical temperature deviations.

Taybetmendiyên sereke:

  • Simultaneous display of current, minimum, and maximum temperatures.
  • Built-in memory for tracking temperature conditions over time.
  • Precise high and low temperature alarms, adjustable in 1° increments.
  • Submersible temperature probe with a 10-ft (3-m) micro-cable.
  • Multiple mounting options: hook-and-loop strips, wall-mount slots, or flip-open stand.
  • NIST-traceable calibration certificate included.

2. Naveroka pakêtê

Verify that all items listed below are present and in good condition:

  • TRACEABLE Jumbo Calibrated Digital Fridge/Freezer Thermometer (Model AO-94460-73)
  • 1 5-mL Bottle Probe (submersible)
  • NIST-traceable calibration certificate with data
  • Hook-and-loop strips for mounting
  • Magnetic strips for mounting
  • Yek pîlê alkaline AAA

3. Sazkirin

3.1. Sazkirina Pîl

  1. Cihê beşa pîlê li ser pişta yekîneyê bibînin.
  2. Berga beşa pîlê rakin.
  3. Insert the supplied AAA alkaline battery, ensuring correct polarity (+/-).
  4. Qapaxa beşa pîlê bi ewlehî biguhezînin.

3.2. Danîna Sondajê

The bottle probe is designed to buffer rapid temperature changes, providing a more stable and accurate reading of the stored contents. The 10-ft (3-m) micro-cable allows the probe to be placed inside the monitored environment while the main unit remains outside.

  • Place the bottle probe inside the refrigerator, freezer, or other environment where temperature monitoring is required. Ensure the probe is positioned to accurately reflect the temperature of the items being stored.
  • The micro-cable is thin enough to allow refrigerator or freezer doors to close without damaging the cable or compromising the seal.
Person placing a bottle probe inside a refrigerator with the thermometer unit mounted outside.

Image: A person placing a bottle probe inside a refrigerator, demonstrating proper probe placement.

3.3. Sazkirina Yekîneya Sereke

The main thermometer unit can be mounted in several ways:

  • Hook-and-Loop Strips: Attach the adhesive-backed hook-and-loop strips to the back of the unit and a clean, flat surface (e.g., side of a refrigerator, wall).
  • Magnetic Strips: Use the magnetic strips for attachment to metallic surfaces.
  • Wall-Mount Slots: Utilize the integrated slots on the back of the unit to hang it on screws or hooks.
  • Flip-Open Stand: For benchtop use, extend the integrated stand on the back of the unit.
Close-up of a hand interacting with the TRACEABLE thermometer mounted on a refrigerator door.

Image: A hand pressing a button on the TRACEABLE thermometer, which is mounted on the exterior of a refrigerator.

4. Telîmatên Operating

4.1. Power On / Off

The unit powers on automatically upon battery installation. There is no dedicated power button. To turn off, remove the battery.

4.2. Reading Temperatures

The large LCD display shows three temperature readings simultaneously:

  • Germahiya heyî: The real-time temperature measured by the probe.
  • Minimum Temperature (MIN): The lowest temperature recorded since the last reset.
  • Maximum Temperature (MAX): The highest temperature recorded since the last reset.

4.3. Switching Temperature Units (°F/°C)

Bitikîne °F/°C button (if available, or a similar labeled button) to toggle between Fahrenheit and Celsius temperature scales.

4.4. Viewing and Clearing Min/Max Memory

The thermometer automatically records the minimum and maximum temperatures reached since the last memory reset. These values are continuously displayed.

  • To clear the MIN/MAX memory and begin a new recording cycle, press the ZELAL button. The display will show the current temperature for MIN and MAX until new minimum and maximum values are recorded.

4.5. Sazkirina Alarman

The thermometer features programmable high and low temperature alarms. An alarm will sound when the temperature exceeds the high set point or falls below the low set point. The alarm continues to sound even if the temperature returns to the non-alarm range until acknowledged.

  1. Bitikîne DANÎN bişkojka ku têkevin moda mîhengê alarmê.
  2. Bi kar tînin UP û JÊR arrow buttons to adjust the desired high temperature alarm limit.
  3. Rojnamevanî DANÎN again to confirm the high limit and proceed to set the low temperature alarm limit.
  4. Bi kar tînin UP û JÊR arrow buttons to adjust the desired low temperature alarm limit.
  5. Rojnamevanî DANÎN a third time to exit alarm setting mode and save the settings.
  6. To enable or disable the alarm, press the ALARM ON / OFF button. An alarm icon will typically appear on the display when the alarm is active.
  7. To silence a sounding alarm, press any button. The alarm will reactivate if the temperature remains outside the set limits.

5. Maintenance

5.1. Paqijkirin

Regular cleaning helps maintain the accuracy and longevity of your thermometer.

  • Wipe the main unit and probe with a damp cloth. A mild soap solution can be used if necessary.
  • Do not use abrasive cleaners or solvents, as these may damage the plastic casing an jî nîşandanê.
  • Ensure the main unit does not get wet, as it is not waterproof. The probe is submersible.

5.2. Guhertina Pîl

When the display becomes dim or the unit stops functioning, it is time to replace the battery. Refer to Section 3.1 for battery installation instructions.

5.3. Probe Care

The bottle probe is designed for durability. Avoid sharp bends or kinks in the cable, which could damage the internal wiring. The probe is freezer safe and can remain in the monitored environment continuously.

6. Destpêkirin

If your thermometer is not functioning as expected, please refer to the following common issues and solutions:

PirsegirêkSedema gengazÇare
Nîşandan tune ye an jî dîmender tarî yePîlê mirî an bi xeletî hatî saz kirinReplace the AAA battery, ensuring correct polarity.
Xwendinên germê yên çewtProbe not properly placed or damagedEnsure the probe is fully immersed or correctly positioned. Inspect the probe and cable for damage.
Alarm nayêAlarm disabled or settings incorrectVerify that the alarm is enabled (check for alarm icon) and that high/low limits are set appropriately.
MIN/MAX values not resettingCLEAR button not pressedBitikîne ZELAL button to reset the memory.

7. Specifications

TaybetîHûrî
Hejmara ModelAO-94460-73
Range Germahiya−58 to 158°F (–50 to 70°C)
Resolution0.1°
Tamî±1°C
Dirêjahiya Kabloya Sondê10 ft (3 m) micro-cable
Çavkaniya Hêzê1 x AAA batarya alkalîn
Type DisplayLCD dîjîtal
Taybetmendiya TaybetHigh Accuracy, NIST-traceable calibration
Talîmatên Lênêrîna HilberêFreezer Safe (probe)
Vebijarkên MountingHook-and-loop, Magnetic, Wall-mount, Benchtop stand

8. Garantî

This TRACEABLE product is warranted to be free from defects in material and workmanship for a period of one year from the date of purchase. This warranty does not cover damage caused by accident, misuse, abuse, alteration, or improper operation. If service is required during the warranty period, please contact customer support.

9. Piştgiriya Mişterî

For technical assistance, warranty claims, or general inquiries, please contact TRACEABLE customer support. Refer to the contact information provided with your purchase documentation or visit the official TRACEABLE webmalper ji bo hûrguliyên piştgiriyê yên herî dawî.

Çavkaniyên Serhêl: