Rebel RB-4003

Rebel POWER-1000 Pure Sine Wave UPS Inverter User Manual

Model: RB-4003 | Brand: Rebel

1. Destpêk

Thank you for choosing the Rebel POWER-1000 Pure Sine Wave UPS Inverter. This device is designed to provide stable and safe emergency power for various applications, including central heating furnaces, heat pumps, refrigerators, and other RTV/AGD systems. It features a pure sine wave output, ensuring compatibility with sensitive electronic and inductive loads, and offers three operating modes: emergency power supply (UPS), rectifier (charger), and inverter.

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your POWER-1000 inverter. Please read it thoroughly before use and retain it for future reference.

2. Telîmatên Ewlekariyê

Ji bo rêgirtina li birîndarbûn an zirara li cîhazê, her gav tedbîrên ewlehiyê yên jêrîn bişopînin:

  • Ewlehiya Elektrîkê: Ensure the device is connected to a properly grounded power outlet. Do not open the casing; di hundir de ti parçeyên ku ji hêla bikarhêner ve werin tamîrkirin nînin. Hemû tamîrkirin ji karmendên pispor re bişînin.
  • Têkiliya Pîlê: Connect the battery with correct polarity (red to positive, black to negative). Incorrect connection can cause severe damage to the inverter and battery. Use a 12V DC battery with a capacity between 50-200 Ah (55 Ah suggested).
  • Perwanekirin: Ensure adequate ventilation around the unit. Do not block the fan or ventilation openings. Overheating can lead to device malfunction or damage.
  • Dor: Operate the device within the specified temperature range of 0 - 40°C and humidity of 10 - 90%. Avoid direct sunlight, moisture, dust, and corrosive environments.
  • Parastina Zêdebar: Do not exceed the rated power of 700 W. The device is equipped with overload protection, but continuous overloading can shorten its lifespan.
  • Têkiliya Şile: Keep the device away from liquids. In case of accidental liquid contact, immediately disconnect power and consult a service technician.
  • Zarok û Pîvan: Amûrê ji zarok û heywanên heywanan dûr bigirin.

3. Components Product

Familiarize yourself with the main components of your Rebel POWER-1000 UPS Inverter:

Pêşde view of Rebel POWER-1000 UPS Inverter showing the LED display and main power switch.

Wêne 3.1: Panela Pêşî
This image displays the front of the Rebel POWER-1000 inverter, featuring the LED display which shows operational status, battery charge, and load level. Below the display is the main ON/OFF switch.

Mezinkirin view of Rebel POWER-1000 UPS Inverter with battery cables, AC input, and output sockets.

Wêne 3.2: Panela Paşîn li Serview
This image shows the rear panel of the inverter. Visible components include the cooling fan, circuit breaker, two output sockets, battery connection terminals (red and black cables), and the AC input socket.

Close-up of the rear panel connections on Rebel POWER-1000 UPS Inverter.

Figure 3.3: Rear Panel Connections Detail
Nêzîktir view of the rear panel, highlighting the 'OUTPUT' sockets for connecting appliances, the 'BATTERY +12V' terminals for external battery connection, the 'AC INPUT 230V' for mains power, and the 'CIRCUIT BREAKER' for protection.

Pêkhateyên sereke:

  • Dîmendera LED: Provides real-time information on operating status, battery charge level, and load level.
  • Main ON/OFF Switch: Controls the power to the inverter.
  • Soketên Derketina AC: Two 230V AC sockets for connecting your devices.
  • Battery Terminals (12V DC): Connect to an external 12V DC battery. Ensure correct polarity.
  • AC Input (230V): Connects the inverter to the mains power supply for charging the battery and providing power in UPS mode.
  • Fanê sarkirinê: Dissipates heat generated during operation.
  • Çêkerê Çerxê: Provides protection against overcurrent.

4. Sazkirin

Follow these steps to set up your Rebel POWER-1000 UPS Inverter:

  1. Vekirin: Carefully remove the inverter from its packaging. Inspect for any signs of damage.
  2. Cihkirin: Place the inverter on a stable, flat surface in a well-ventilated area, away from direct sunlight, heat sources, and moisture. Ensure sufficient space around the unit for airflow.
  3. Têkiliya Pîlê:
    • Ensure the inverter is switched OFF.
    • Girêdan bike sor kabloya pîlê ber bi erênî (+) terminal of your 12V DC battery.
    • Girêdan bike reş kabloya pîlê ber bi neyînî (-) terminal of your 12V DC battery.
    • Tighten all connections securely to prevent arcing.
  4. Têkiliya Serek AC: Plug the inverter's AC input cable into a standard 230V AC wall outlet.
  5. Girêdana Amûrê: Plug the devices you wish to power into the 230V AC output sockets on the rear of the inverter. Ensure the total power consumption of connected devices does not exceed 700 W.

5. Telîmatên Operating

The Rebel POWER-1000 operates in three main modes:

  • UPS Mode (Emergency Power Supply): When connected to mains power, the inverter charges the external battery and simultaneously supplies power to connected devices. In case of a power outage, it automatically switches to battery power within <4 ms, providing uninterrupted power.
  • Rectifier Mode (Battery Charger): When connected to mains power without any load, the inverter functions as a battery charger, replenishing the external battery.
  • Moda Inverter: When not connected to mains power, the inverter converts 12V DC battery power into 230V AC pure sine wave power for your connected devices.

Starting the Inverter:

  1. Ensure all connections (battery, AC input, loads) are secure.
  2. Press the main ON/OFF switch on the front panel. The LED display will illuminate, indicating the current operating status, battery charge, and load level.
  3. The inverter will automatically select the appropriate operating mode based on the presence of mains power and connected loads.

Agahiyên Dîmendera LED:

The clear LED display provides crucial information:

  • Volta Inputtage: Shows the incoming AC voltage from the mains.
  • Output Voltage: Displays the 230V AC output voltage.
  • Battery Voltage: Nîşan dide voltage of the connected 12V battery.
  • Asta barkirinê: Ji sedî nîşan didetage of the inverter's capacity being used by connected devices.
  • Rewşa Xebatê: Icons or indicators for mains power, battery power, charging, and fault conditions.

6. Maintenance

Parastina birêkûpêk performansa çêtirîn û temendirêjiya învertera we misoger dike:

  • Paqijî: Periodically clean the exterior of the inverter with a soft, dry cloth. Ensure the cooling fan and ventilation openings are free from dust and debris. Do not use liquid cleaners.
  • Kontrola Pîlê: Regularly check battery terminals for corrosion and ensure connections are tight. If using a lead-acid battery, check electrolyte levels if applicable and top up with distilled water as needed (refer to battery manufacturer's instructions).
  • Perwanekirin: Always ensure the inverter has adequate ventilation. Do not place objects on top of the unit or block its air vents.
  • Embarkirinî: If storing the inverter for an extended period, disconnect it from both mains power and the battery. Store in a cool, dry place. For optimal battery health, fully charge the battery before storage and recharge it every 3-6 months.

7. Destpêkirin

If you encounter issues with your Rebel POWER-1000, refer to the following table:

PirsegirêkSedema gengazÇare
Inverter does not turn onNo battery connected or battery discharged; Main switch off; Blown circuit breaker.Connect a charged battery; Turn on the main switch; Check and reset the circuit breaker on the rear panel.
Derketina AC tuneOverload; Short circuit; Battery low; Inverter fault.Reduce connected load; Check for short circuits in connected devices; Recharge or replace battery; If problem persists, contact support.
Pîl nayê barkirinAC input not connected; AC input voltage too low/high; Battery fault.Ensure AC input cable is securely plugged in; Check mains voltage; Test battery or replace if faulty.
Overload warning on displayTotal power of connected devices exceeds 700 W.Disconnect some devices to reduce the load below 700 W.
Unit is unusually hotBlocked ventilation; Excessive load; High ambient temperature.Ensure vents are clear; Reduce load; Move unit to a cooler environment.

If the problem persists after attempting these solutions, please contact Rebel customer support or your retailer.

8. Specifications

Technical specifications for the Rebel POWER-1000 UPS Inverter (Model RB-4003):

TaybetîSpecification
Hêza Nirxkirî700 W (1000 VA)
Cureyê Pîl12 V DC
Max Battery Voltage15 V DC
Volta Inputtage Range190 - 260 V AC
Frequency Input45 - 60 Hz
Output Voltage (AC)230 V AC +/-5% (Inverter: 230 V AC +/-3%)
Frequency Output50/60 Hz +/-0.5 Hz
Pêla DerketîPave Sine Wave
Efficiency Output>= 85% (DC to AC)
Battery Charging CurrentMax. 10 A
Kapasîteya Pîlê ya Pêşniyarkirî50-200 Ah (suggested: 55 Ah)
Wexta barkirinê ya texmînkirî4-14 hours (dependent on battery capacity)
Demê guherandinê=<4 ms
ParastinOverload, Short Circuit, Over/Under Voltage
Germahiya xebitandinê0 - 40°C
Humidity Operating10 - 90%
Pîvan (L x W x H)336 x 143 x 178 mm
Pîvan4.3 kg

9. Garantî û Piştgirî

The Rebel POWER-1000 UPS Inverter is manufactured by Rebel. For warranty information, please refer to the warranty card included with your product or consult the retailer from whom you purchased the device. Keep your proof of purchase for warranty claims.