SINOTIMER TM617

SINOTIMER TM617 Digital Programmable Timer Switch User Manual

Model: TM617

1. Destpêk

The SINOTIMER TM617 is a versatile digital programmable timer switch designed to automate the control of various electrical devices. It allows for precise scheduling of ON/OFF cycles over a 7-day period, making it suitable for a wide range of applications. This manual provides detailed instructions for the installation, operation, and maintenance of your TM617 timer switch.

Common applications include controlling street lights, neon signs, lamps, water heaters, air conditioners, billboards, electric ovens, boosters, sprayers, fillers, preheaters, agricultural equipment, and broadcasting equipment. The device features a built-in battery to preserve program settings during power interruptions, ensuring reliable operation. It is characterized by low power consumption, a high-precision CMOS chip, strong anti-interference capabilities, and user-friendly programming. The TM617 is IEC 60367 and CE certified.

2. Taybetmendiyên Hilberê

  • Ideal for household and industrial applications, suitable for panel mounting.
  • High load capacity: Supports up to 3500 Watts / 16 Amps with 1NO+1NC contact configuration.
  • Flexible programming: Features 24-hour / 7-day weekly programming capabilities.
  • Memory retention: Integrated rechargeable battery ensures program settings are saved during power outages.
  • Accuracy: Automatic error correction of +/- 30 seconds per week.
  • Multiple programs: Offers 16 ON/OFF program settings with repeat function.
  • Manual control: Includes a manual ON/OFF override function.
  • Clear display: Large LCD for easy viewing of time and program status.

3. Specifications Teknîkî

CinsTM-617
Range Germahiya-20 °C heta +50 °C
Navê min100-130 V AC (Note: 220V variant also available)
Vexwarina Hêzê4.5 VA (MAX)
PêşkêşîLCD
Switching Contact1 Changeover Switch (1NO+1NC)
Programs16 ON/OFF settings per day or week
Hysteresis2 seconds/day (at 25°C)
Navbera hindiktirîn1 minute
Switching Capacity16 (8) A, 250 V AC
Backup Bîra60 days (via internal battery)
Rêzeya demjimêrê1 deqîqe heta 168 saetan
Battery Navxweyî1.2 V, 40 mA
Average Error±1 second/24 hours (at 25°C)

4. Sazkirin û Sazkirin

Hişyariya Ewlekariyê: Installation should only be performed by a qualified electrician. Ensure power is disconnected before installation to prevent electric shock.

4.1 Vekirin û Teftîşkirin

Carefully remove the TM617 timer switch from its packaging. Inspect the device for any signs of damage. The package should include the timer switch and mounting screws.

SINOTIMER TM617 Digital Time Switch with protective cover open and mounting screws

Figure 1: The SINOTIMER TM617 Digital Time Switch with its protective cover open, revealing the display and buttons. Two mounting screws are shown next to the device, indicating included accessories for installation.

4.2 Çêkirin

The TM617 is designed for panel mounting. Use the provided screws to secure the timer switch to a suitable panel or enclosure. Ensure adequate ventilation around the device.

Paş view of SINOTIMER TM617 Digital Time Switch showing mounting points and terminals

jimar 2: Paş view of the SINOTIMER TM617 Digital Time Switch, illustrating the mounting points and terminal block for electrical connections. This view is crucial for proper installation.

4.3 Diagrama Têlkirinê

Refer to the wiring diagram below for correct electrical connections. Ensure all connections are secure and comply with local electrical codes.

Technical drawing of SINOTIMER TM617 with dimensions and wiring diagram

Figure 3: Technical drawing of the SINOTIMER TM617 Digital Time Switch, showing its dimensions (72mm x 72mm x 48mm) and an exploded view. The diagram also includes a basic wiring schematic, indicating where to connect the power input and load output.

The diagram typically shows terminals for power input (L, N) and load output (L, N, or switched live). The TM617 has a 1NO+1NC contact, meaning it can switch between two states. Consult the markings on the device for specific terminal assignments.

5. Telîmatên Operating

The TM617 features an intuitive button layout for setting the time and programming schedules.

Pêşde view of SINOTIMER TM617 Digital Time Switch with LCD display and control buttons

Wêne 4: Pêşî view of the SINOTIMER TM617 Digital Time Switch, highlighting the LCD display and the various control buttons for setting time and programming functions.

5.1 Fonksiyon Bişkojk

  • Ockkona Saetê: Used to set the current time and day.
  • P: Program button, used to enter and navigate through programming modes.
  • D+: Day button, used to adjust the day of the week.
  • H+: Hour button, used to adjust the hour.
  • M+: Minute button, used to adjust the minute.
  • C/R: Cancel/Recall or Reset button. Press to clear settings or reset the device.
  • Hand Icon: Manual override button, to switch the output ON/OFF manually, overriding current program.

5.2 Initial Setup and Reset

Upon first use or after a prolonged power outage, the display may be blank or show incorrect time. Press the C/R button (often recessed, requiring a pointed object) to reset the device. The internal battery will charge once power is supplied to the unit.

5.3 Danîna Dem û Roja Niha

  1. Bişkojk û bigire Ockkona Saetê pişkov.
  2. Dema ku digire Ockkona Saetê bişkok, pêl D+ ji bo danîna roja niha ya hefteyê.
  3. Dema ku digire Ockkona Saetê bişkok, pêl H+ ji bo danîna saeta heyî.
  4. Dema ku digire Ockkona Saetê bişkok, pêl M+ ji bo danîna deqeya niha.
  5. Serbest berdan Ockkona Saetê bişkok. Dem niha hatiye danîn.

5.4 Bernamekirina Çerxên VEKIRIN/GIRTINÊ

The TM617 allows for up to 16 ON/OFF programs. Each program consists of an ON time and an OFF time, and can be set for specific days or groups of days.

  1. Bitikîne P button once to enter program setting mode. The display will show "1 ON".
  2. Rojnamevanî D+ to select the desired day(s) for this program. Options typically include individual days (MO, TU, WE, etc.), weekdays (MO TU WE TH FR), weekends (SA SU), or all days (MO TU WE TH FR SA SU).
  3. Rojnamevanî H+ ji bo danîna saeta ON.
  4. Rojnamevanî M+ ji bo danîna deqeya ON.
  5. Bitikîne P button again. The display will show "1 OFF".
  6. Repeat steps 2-4 to set the OFF time for the first program.
  7. Bitikîne P button again to move to the next program ("2 ON"). Repeat the process for up to 16 programs.
  8. To exit program setting mode and return to the current time display, press the Ockkona Saetê pişkov.

5.5 Destnîşana Destûrî

Bitikîne Hand Icon button to manually switch the output state (ON/OFF) without affecting the programmed schedule. This is useful for temporary control. The display will indicate the manual override status (e.g., "ON" or "OFF" with a hand icon).

6. Maintenance

The SINOTIMER TM617 is designed for low maintenance. Follow these guidelines to ensure optimal performance:

  • Paqijî: Amûrê bi qumaşek nerm û hişk paqij bikin. Paqijker an çareserkerên aşınker bikar neynin.
  • Pîl: The internal rechargeable battery is designed for long life and typically does not require replacement. It charges automatically when the device is powered. If the display remains blank after power is restored, allow some time for the battery to charge.
  • Dor: Ensure the operating environment stays within the specified temperature range (-20 °C to +50 °C) and is free from excessive dust or moisture.

7. Destpêkirin

PirsegirêkSedema gengazÇare
Nîşan vala ye.No power supply; internal battery discharged.Check power connections. Ensure the device is receiving power. Allow time for the internal battery to charge. Press the C/R button to reset.
Timer does not switch ON/OFF as programmed.Incorrect program settings; manual override active; incorrect current time/day.Verify program settings (ON/OFF times, days). Check if manual override is active and switch to AUTO mode if necessary. Ensure current time and day are set correctly.
Dem nerast e.Minor drift (normal for electronic timers); device needs reset.The device has an automatic error correction of +/- 30 seconds per week. If significantly off, reset the device using the C/R button and re-set the current time.
Load does not turn ON/OFF.Incorrect wiring; faulty load; timer malfunction.Check wiring according to the diagram. Test the load directly to ensure it is functional. If all else fails, the timer may be faulty and require replacement.

8. Agahiyên Ewlekariyê

  • Always disconnect power before installing, wiring, or servicing the device.
  • Do not exceed the maximum load capacity of 16A / 3500W.
  • Ensure proper grounding and adherence to all local electrical codes.
  • Do not expose the device to water or extreme humidity.
  • Hewl nedin ku cîhazê bi xwe vekin an tamîr bikin. Bi karmendên pispor re têkilî daynin.
  • Dûr negihêjin zarokan.

9. Garantî û Piştgirî

For warranty information and technical support, please refer to the purchase documentation or contact your retailer. SINOTIMER products are designed for reliability, and support is available for any operational issues or defects.

Ji bo alîkariya zêdetir, hûn dikarin serdana SINOTIMER Brand Store on Amazon.

© 2023 SINOTIMER. All rights reserved.

Ev destan bêyî agahdarkirinê dikare were guhertin.

Ask a question about this manual